EN15650防火擋板歐盟CE認證_CE Marking for Fire dampers
發布日期:2024-6-17 10:34:48 閱讀次數:1048
防火擋板根據EN 15650:2010進行CE認證,并根據EN 1366-2和EN 13503-3標準進行耐火測試。防火擋板用作通風系統中的安全相關部件,以防止火災和煙霧通過管道傳播。防火擋板EN15650歐盟CE認證及EN1366-2耐火測試,請咨詢南京睿督工程師,咨詢電話:025-86583475。
Fire dampers are CE-marked according EN 15650:2010 and tested according to EN 1366-2 and EN 13501-3 standard. Fire dampers are used as safety-related components in ventilation systems to prevent fire and smoke spreading through ducting.
EN 15650:2010 Ventilation for buildings - Fire dampers
EN 15650:2010 建筑通風,防火擋板
This European Standard applies to fire dampers that are to be used in conjunction with fire separating elements to maintain fire compartments. This standard specifies requirements and gives reference to the test methods defined for fire dampers, which are intended to be installed in Heating, Ventilating and Air Conditioning (HVAC) installations in buildings. All fire dampers close automatically in response to raised temperatures indicating fire. Details are given for the provision of evaluation of conformity and marking of fire dampers.
EN 15650適用于與防火分隔元件一起使用以維持防火分區的防火閥。EN 15650規定了安裝在建筑物供暖、通風和空調(HVAC)裝置中的防火閥的要求,并參考了其測試方法。所有防火閥都會自動關閉,以響應指示火災的升高溫度。提供了防火閥一致性評估和標記的詳細信息。
EN15650防火擋板歐盟CE認證測試項目:
Response delay (response time):
- closure time
Operational reliability:
- cycling (Cycling 0 or 5)
Fire resistance
- integrity
- insulation
- smoke leaka
Durability of operational reliability:
- open and closing cycle tests (Cycling 300 or 10 000 or 20 000)
EN15650防火擋板歐盟CE認證模式:
EN15650防火擋板歐盟CE標簽參考
南京睿督公司咨詢電話:025-8658 3475 400-603-6575
網址:www.shseg-gps.com www.cprce.com
郵箱:info@hksmartps.com
微信:firetesting 或 17714189018
…
Fire dampers are CE-marked according EN 15650:2010 and tested according to EN 1366-2 and EN 13501-3 standard. Fire dampers are used as safety-related components in ventilation systems to prevent fire and smoke spreading through ducting.
EN 15650:2010 Ventilation for buildings - Fire dampers
EN 15650:2010 建筑通風,防火擋板
This European Standard applies to fire dampers that are to be used in conjunction with fire separating elements to maintain fire compartments. This standard specifies requirements and gives reference to the test methods defined for fire dampers, which are intended to be installed in Heating, Ventilating and Air Conditioning (HVAC) installations in buildings. All fire dampers close automatically in response to raised temperatures indicating fire. Details are given for the provision of evaluation of conformity and marking of fire dampers.
EN 15650適用于與防火分隔元件一起使用以維持防火分區的防火閥。EN 15650規定了安裝在建筑物供暖、通風和空調(HVAC)裝置中的防火閥的要求,并參考了其測試方法。所有防火閥都會自動關閉,以響應指示火災的升高溫度。提供了防火閥一致性評估和標記的詳細信息。
EN15650防火擋板歐盟CE認證測試項目:
Response delay (response time):
- closure time
Operational reliability:
- cycling (Cycling 0 or 5)
Fire resistance
- integrity
- insulation
- smoke leaka
Durability of operational reliability:
- open and closing cycle tests (Cycling 300 or 10 000 or 20 000)
EN15650防火擋板歐盟CE認證模式:
建筑通風防火擋板,需要按照AVCP System 1的要求進行認證,即需要具有EN 15650認證能力的公告號(NB機構)參與,需要工廠審核和抽樣進行初步型式測試。

EN15650防火擋板歐盟CE標簽參考

南京睿督公司咨詢電話:025-8658 3475 400-603-6575
網址:www.shseg-gps.com www.cprce.com
郵箱:info@hksmartps.com
微信:firetesting 或 17714189018
…